Industrial Power Cables / 0.6/1kV - 35kV
Engineered for the grid.
Built to last decades.
Jinda XLPE-insulated power cables are manufactured to IEC 60502, GB/T 12706, and BS 6622 standards across five production bases. Each reel is traceable from copper rod to final delivery -- supplying utilities, EPC contractors, and industrial plants in over 50 countries.
- Voltage Range
- 0.6/1 kV -- 26/35 kV
- Conductor
- Class 1, 2, 5 Cu / Al
- Insulation
- XLPE / PVC / EPR / LSZH
- Standards
- IEC · GB · BS · UL · VDE
Series
YJV / YJV22
Cores
1 / 2 / 3 / 4 / 5
Section
1.5 -- 800 mm²
38+
Years
5
Bases
50+
Countries
3000+
SKUs
Applications
Specified by engineers across heavy industry and infrastructure.
Power Transmission
Utility & Grid Distribution
Medium-voltage XLPE cables for substations, primary distribution networks, and ring main units up to 35kV.
Specifications →Renewable Energy
Wind, Solar & Energy Storage
DC solar cables (TÜV / EN 50618), torsion-resistant turbine cables, and BESS interconnect systems.
Specifications →Industrial Automation
Robotics & VFD Systems
Continuous-flex robotic cables, shielded VFD cables, and instrumentation cables for harsh environments.
Specifications →
Rail Transit
Metro & High-Speed Rail
LSZH fire-resistant cables compliant with EN 50264 and EN 45545-2 hazard level HL3 for rolling stock.
Specifications →
Petrochemical
Oil, Gas & Refineries
Flame-retardant and fire-resistant cables (IEC 60332-3, IEC 60331) for hazardous-area installations.
Specifications →Port & Marine
Cranes, Shipyards & Offshore
Reeling drum cables, marine cables (IEC 60092), and heavy-duty rubber cables for STS/RTG cranes.
Specifications →
Total Area
470,000 m²
Investment
RMB 3 B
Patents
30


Export Sales
info@jindacablegroup.comHeadquarters
Jinan, Shandong, China
Address
No. 1377 Wode Ave, Changqing District
Manufacturing Capability
Five production bases. One quality standard.
Tianjin · Liaoning · Heilongjiang · Shandong · Xi'an. Each base operates under a unified MES digital management system, with full traceability from copper rod to delivered reel. Products serve EPC contractors, utilities, and industrial OEMs in 50+ countries.
Product Reference
Cable Model Cross-Reference Table
Chinese GB standard cable models mapped to international equivalents across EU/CE, UL (North America), EAC/GOST (Russia/CIS), SAA (Australia/New Zealand), and BS/UKCA (UK) standards. Use this table to identify equivalent specifications for your project requirements.
| Chinese Model | Description | 🇨🇳 GB Standard | 🇪🇺 CE / EU | 🇺🇸 UL (North America) | 🇷🇺 EAC / GOST | 🇦🇺 SAA (AU/NZ) | 🇬🇧 BS / UKCA |
|---|---|---|---|---|---|---|---|
| Building Wire & Flexible Conductors | |||||||
| BV | Single-core solid conductor building wire | GB/T 5023.3 | H05V-U / H07V-U | THHN / THWN-2 | -- | V90 Solid PVC Wire | BS 6241Y Solid PVC |
| BVR | Single-core flexible conductor building wire | GB/T 5023.3 | -- | -- | -- | V90 Flexible PVC | BS 6241B Flexible PVC |
| RV | Single-core flexible wire (equipment wiring) | GB/T 5023.5 | H05V-K / H07V-K | UL1015 Hook-up Wire | -- | -- | -- |
| BVV | PVC insulated round sheathed cable | GB/T 5023 | -- | -- | -- | -- | -- |
| RVV | Flexible multi-core round sheathed cable | GB/T 5023.5 | -- | -- | -- | -- | -- |
| RVS | Twisted-pair fire alarm wire | GB/T 5023 | -- | -- | -- | -- | -- |
| RVVP | Shielded flexible multi-core cable | GB/T 5023 | -- | -- | -- | -- | -- |
| Low Voltage Power Cables (PVC Insulated) | |||||||
| VV | LV PVC insulated & sheathed power cable | GB/T 12706 | NYY | THWN-2 Multi-core | ГОСТ 16442-88 / ВВ | V90 PVC Unarmoured | BS 6243Y PVC Sheathed |
| VV22 | Steel tape armoured PVC power cable | GB/T 12706 | NYBY | STA Power Cable | ВВ-СБ / ВБбШв | V90 PVC STA | BS STA |
| VV32 | Steel wire armoured PVC power cable | GB/T 12706 | NYMB | SWA Power Cable | ВВ-ПБ | V90 PVC SWA | BS 6244Y SWA |
| Low Voltage Power Cables (XLPE Insulated) | |||||||
| YJV | LV XLPE insulated PVC sheathed power cable | GB/T 12706 | N2XY / NA2XY | XHHW-2 XLPE | АВВГ | V90 XLPE Unarmoured | BS XLPE Unarmoured |
| YJV22 | Steel tape armoured XLPE power cable | GB/T 12706 | NA2XS2Y / N2XS2Y | XHHW-2 STA | АВВГ-СБ / АПвБШв | V90 XLPE STA | BS STA |
| YJV32 | Steel wire armoured XLPE power cable | GB/T 12706 | N2XSEBY | XHHW-2 SWA | АВВГ-ПБ | V90 XLPE SWA | BS SWA XLPE |
| Medium & High Voltage Power Cables (XLPE) | |||||||
| YJV22 MV 10kV | 8.7/15kV medium voltage XLPE armoured | GB/T 12706 (MV) | NA2XS2Y / N2XS2Y | MV-90 STA | АВВГ-СБ 6-35кВ | MV V90 XLPE STA | BS MV XLPE SWA |
| YJV22 HV 35kV | 26/35kV high voltage XLPE armoured | GB/T 12706 (HV) | N2XS2Y (HV) | MV-90 STA HV | АВВГ-СБ 6-35кВ | MV V90 XLPE STA | BS MV XLPE SWA |
| Control Cables | |||||||
| KVV | PVC insulated control cable (unshielded) | GB/T 9330 | H05VV-U / NYY-O | UL1277 Unshielded Tray | КВВ | Multi-core Unshielded | BS Unshielded Control |
| KVVP | PVC insulated shielded control cable | GB/T 9330 | H05VVC4V5-K / LiYCY | UL1277 Shielded Tray | КВВЭ | Multi-core Shielded | BS Screened Control |
| KVVR | Flexible PVC control cable (unshielded) | GB/T 9330 | H05VV-F | Flex UL1277 Unshielded | КВВГ | Flexible Unshielded | -- |
| KVVRP | Flexible PVC shielded control cable | GB/T 9330 | H05VVC4V5-K Flex | Flex UL1277 Shielded | КВВГЭ | Flexible Shielded | BS Flexible Screened |
| Rubber Insulated & Sheathed Cables | |||||||
| YZ | Medium-duty rubber sheathed flexible cable | GB/T 5013 | H05RN-F | SJT Light Duty | ШВВ | Light Duty Rubber | -- |
| YZW | Medium-duty weather/oil-resistant rubber cable | GB/T 5013 | H05RN-F (Oil) | SJTOW Oil Resistant | ШВВТ | Oil Resistant Light | H05RN-F |
| YC | Heavy-duty rubber sheathed flexible cable | GB/T 5013 | H07RN-F | SJOOW Medium Heavy | КГ | -- | -- |
| YCW | Heavy-duty weather/oil-resistant rubber cable | GB/T 5013 | H07RN-F (Oil) | SOOW Heavy Duty | КГТП / КГТП-ХЛ | Heavy Duty Oil Resistant | H07RN-F |
| YH | Welding machine rubber cable | JB/T 8137 | H01N2-D / H01N2-E | UL 1581 Welding | -- | -- | -- |
| Solar PV & Renewable Energy Cables | |||||||
| PV1-F | Photovoltaic DC solar cable | GB/T 32129 | PV1-F / H1Z2Z2-K | UL4703 Solar PV DC | СИП-С | 1000V/1500V DC SAA | BS EN PV1-F |
| Mineral Insulated Cables (Fire Resistant) | |||||||
| BTTZ | Rigid copper sheathed mineral insulated cable | GB/T 13033 | BI | UL504 Rigid MI | МИК | MIC Mineral Insulated | BS MIC (BS 6387) |
| BTTVZ | Rigid mineral insulated cable with outer sheath | GB/T 13033 | BIC | UL504 Jacketed Rigid MI | МИК-П | -- | -- |
| BBTRZ | Flexible mineral insulated fire resistant cable | GB/T 34926 | MICC Flexible MI | UL504 Flexible MI | ГИК | -- | -- |
| LSZH Low Smoke Zero Halogen Cables | |||||||
| WDZ-YJV | LSZH flame retardant XLPE power cable (unarmoured) | GB/T 19666 | -- | -- | -- | V90 LSZH | -- |
| WDZ-YJV22 | LSZH flame retardant XLPE steel tape armoured | GB/T 19666 | -- | -- | -- | -- | BS LSZH STA |
| WDZ-YJY | LSZH flame retardant XLPE with PE outer sheath | GB/T 19666 | -- | -- | -- | -- | BS LSZH (WDZ-YJY) |
| Mining Cables | |||||||
| MYJV | Mining XLPE power cable (unarmoured) | MT/T 818 | N2XY (MYJV) | FR XHHW-2 Mining | АВВнг | -- | -- |
| MYJV22 | Mining XLPE steel tape armoured cable | MT/T 818 | NA2XS2Y (MYJV22) | FR STA Mining | АВВнг-СБ | -- | -- |
| MYJV32 | Mining XLPE steel wire armoured cable | MT/T 818 | -- | FR SWA Mining | АВВнг-ПБ | -- | -- |
Abbreviation Legend
- STA
- Steel Tape Armoured
- SWA
- Steel Wire Armoured
- XLPE
- Cross-linked Polyethylene
- LSZH
- Low Smoke Zero Halogen
- LV
- Low Voltage (≤1kV)
- MV
- Medium Voltage (1-35kV)
- FR
- Flame Retardant
- MI
- Mineral Insulated
- PVC
- Polyvinyl Chloride
- PE
- Polyethylene
Important Notes
- · This table provides general cross-reference guidance only. Exact equivalency depends on specific voltage ratings, conductor cross-sections, and project specifications.
- · A dash (--) indicates no direct equivalent exists in that standard, or the standard does not cover that cable type.
- · Always verify compliance with the applicable local standard and regulatory authority before project specification.
- · Jinda Cable can supply cables to custom international standards upon request. Contact our technical team for OEM/ODM requirements.
Need a Custom Specification?
Our engineers can match any international standard. Request a technical datasheet or submit your project specifications.
Model Reference
Product Model Comparison Table
Use the table below to cross-reference model numbers against key technical specifications. All models are available for custom configuration -- contact our technical team for unlisted variants.
| Model No. | Voltage Grade | Conductor | Conductor Class | Insulation | Sheath | Armor | No. of Cores | Cross Section | Rated Temp. |
|---|---|---|---|---|---|---|---|---|---|
* Specifications subject to change without notice. Contact our technical team to confirm before procurement. Custom conductor sizes, core configurations, and sheath materials are available on request.
Request a QuoteGlobal Standards Reference
International Standards Cross-Reference
Jinda cable products are engineered to meet major international standards. Use this reference table to identify the equivalent standard for your region -- whether you specify to IEC, BS, GB/T, UL, VDE, EN, or AS/NZS.
| Cable Type | IEC | GB/T | BS | EN | UL | VDE | AS/NZS | Jinda Series |
|---|---|---|---|---|---|---|---|---|
LV Power Cable 0.6/1 kV, XLPE insulated | IEC 60502-1 | GB/T 12706-1 | BS 6622 | -- | UL 44 | VDE 0276 | AS/NZS 1429.1 | YJV / YJLV |
MV Power Cable 3.6/6 kV - 26/35 kV, XLPE | IEC 60502-2 | GB/T 12706-2/3 | BS 6622 | -- | -- | VDE 0276-620 | AS/NZS 1429.2 | YJV22 / YJLV22 |
PVC Power Cable 0.6/1 kV, PVC insulated | IEC 60502-1 | GB/T 12706-1 | BS 6004 | -- | -- | -- | -- | VV / VLV |
Fire Resistant Cable Circuit integrity under fire | IEC 60331 | GB/T 19216 | BS 6387 | EN 50200 | -- | -- | AS/NZS 3013 | NHYJV / NHYV |
Flame Retardant Cable Flame propagation resistance | IEC 60332-1/3 | GB/T 18380 | -- | EN 60332 | -- | -- | -- | ZR-YJV / ZR-VV |
LSZH / LSHF Cable Low smoke zero halogen | IEC 60754 / IEC 61034 | GB/T 17650 / 17651 | -- | EN 50525-3-11 | -- | -- | -- | WDZA-YJY |
Mineral Insulated Cable MICC / BTTZ type | IEC 60702 | GB/T 13033 | BS 6207 | -- | -- | -- | -- | BTTZ / BTTQ |
Flexible Rubber Cable Heavy-duty, EPR/HEPR insulated | IEC 60245 | GB/T 5013 | BS 6007 | -- | UL 62 | -- | AS/NZS 3191 | YC / YCW |
Flexible PVC Cable Light / medium duty, 300/500 V | IEC 60227 | GB/T 5023 | BS 6004 | EN 50525-2-11 | -- | VDE 0281 | -- | RVV / RVVP |
Welding Cable High flexibility, EPR sheathed | IEC 60245-6 | GB/T 5013-5 | -- | -- | -- | VDE 0282-6 | -- | YH / YHF |
PVC Building Wire Fixed wiring, 300/500 V | IEC 60227 | GB/T 5023 | BS 6004 | EN 50525-2-11 | UL 83 | VDE 0281 | AS/NZS 5000.1 | BV / BVR |
LSZH Building Wire Low smoke, halogen free | IEC 60227 / 60754 | GB/T 5023 | BS 7211 | EN 50525-3-11 | -- | -- | -- | WDZB-BYJ |
Solar DC Cable PV string / array cable, 1.5-6 mm² | IEC 62930 | GB/T 37379 | -- | EN 50618 | UL 4703 | -- | -- | PV1-F / H1Z2Z2-K |
Wind Power Cable Torsion-resistant, tower cable | IEC 60502-1 | GB/T 33388 | -- | -- | -- | -- | -- | WTTCEV / WTCEV |
Mining Flexible Cable Coal mine, reeling drum | IEC 60245 | MT/T 818 | -- | -- | -- | -- | -- | MYP / MYPTJ |
Mining Signal Cable Intrinsically safe, monitoring | -- | MT/T 818 | -- | -- | -- | -- | -- | MHYV / MHYVP |
Mining Power Cable Armored, fixed installation | IEC 60502-1 | MT/T 818 | -- | -- | -- | -- | -- | MVV / MVV22 |
Standards Legend:
IEC -- International Electrotechnical Commission GB/T & MT/T -- Chinese National Standards BS -- British Standards EN -- European Standards UL -- Underwriters Laboratories (US) VDE -- German Electrotechnical Standard AS/NZS -- Australian & New Zealand StandardsNeed a standard not listed here?
Jinda's engineering team can assess compliance and provide test reports for region-specific requirements including NEK 606, API RP 14F, and custom OEM specifications.